Dosimetric characterisation of ethylene-propylene based insulating material

TitoloDosimetric characterisation of ethylene-propylene based insulating material
Tipo di pubblicazioneArticolo su Rivista peer-reviewed
Anno di Pubblicazione1990
AutoriOnori, S., Baccaro S., Caccia B., D'Atanasio Paolo, Indovina P.L., Pantaloni M., Petetti E., and Viezzoli G.
RivistaRadiation Protection Dosimetry
Volume34
Paginazione299-302
ISSN01448420
Parole chiaveconference paper, dosimetry, gamma radiation
Abstract

The behaviour of a co-polymer of ethylene and propylene (EPR) based insulating materials irradiated with a gamma ray source has been studied. One of the most relevant effects of the interaction of ionising radiation with polymers is the production of free radicals that can be detected with electron spin resonance (ESR) technique. In the present work samples were irradiated with a 60Co Gammacell source (absorbed dose rate ≃ 0.35 Gy.s-1) and measurements were performed with an X band spectrometer (Varian E112). All samples tested show a well defined ESR signal whose amplitude increases with time. The behaviour at room conditions and dose-effect relationships were investigated. The preliminary results obtained show that the ESR technique can be a useful tool for the quantitative investigation of free radical production and ageing studies in polymeric systems.

Note

cited By 4

URLhttps://www.scopus.com/inward/record.uri?eid=2-s2.0-0025610823&partnerID=40&md5=2519cef2d0923a32aa8912b63e470335
Citation KeyOnori1990299